Siemens -- CR1.pdf

(3681 KB) Pobierz
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01//EN" "http://www.w3.org/TR/html4/strict.dtd">
21T3
SERVICE MANUAL
AEP Model
Chassis No. SCC-L33M-A
CR1
CHASSIS
SPECIFICATIONS
Dimensions and weight
CRT:
Horizontal frequency:
30 kHz .... 130 kHz
(multi-scanning)
50 cm (21“)
Visible diagonals:
50 cm
Refresh rate:
50 kHz .... 170 Hz
Dot pitch:
0.24 mm (aperture grille)
Maximum pixel rate:
300 MHz
Maximal resolution:
1920 × 1440 pixels
Power supply:
switches automatically
100 V .... 240 V, 50 Hz - 60 Hz
Preset picture size (for 4:3 modes):
388 mm ×
291 mm
Dimensions (W ×
H × D):
497 mm ×
502 mm ×
485 mm
Power consumption:
< 135 W (ON, Normal mode)
Weight:
30.5 kg
(see power management):
< 3 W (OFF mode)
Accessories:
Power cable (1.8 m)
data cable (1.8m)
Environmental conditions
Environment class 3K2, IEC 721
Rated range of operation:
Storable display modes:
15 (3 of which are preset)
15 °
C .... 35 °
C
Electrical data
Video:
Humidity:
20 % .... 85 %
analogue, positive, 0.7 Vp-p,
75 Ohm
Limit range of operation:
5
C .... 40
C
Humidity:
20 % .... 85 %
Synchronisation:
Separate Sync. TTL
Composite Sync. TLL/Sync. on
Green
Condensation must be avoided.
COLOR MONITOR
879767318.026.png 879767318.027.png 879767318.028.png 879767318.029.png 879767318.001.png
 
SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes and
bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or
contact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and
mounting hardware have been replaced. Be absolutely certain that you
have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors, that
were installed during a previous repair. Point them out to the customer
and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of
deterioration. Point them out to the customer and recommend their
replacement.
6. Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7. Check the B+ and HV to see if they are specified values. Make sure your
instruments are accurate; be suspicious of your HV meter if sets always
have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs, screws, and
all other exposed metal parts for AC Leakage. Check leakage as
described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital
multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or
battery-operated AC voltmeter. The “limit” indication is 0.75 V, so
analog meters must have an accurate low-voltage scale. The Simpson 250
and Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable. (See Fig. A)
To Exposed Metal
Parts on Set
AC
Voltmeter
(0.75 V)
0.15
F
1.5 k
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
21T3 (E)
2
879767318.002.png 879767318.003.png 879767318.004.png 879767318.005.png 879767318.006.png 879767318.007.png 879767318.008.png 879767318.009.png 879767318.010.png 879767318.011.png 879767318.012.png 879767318.013.png 879767318.014.png 879767318.015.png
 
WARNING!!
NEVER TURN ON THE POWER IN A CONDITION IN WHICH THE
DEGAUSS COIL HAS BEEN REMOVED.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY SHADING AND MARK
ON THE
SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE
PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE
THESE COMPONENTS WITH SONY PARTS WHOSE PART
NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN
SUPPLEMENTS PUBLISHED BY SONY. CIRCUIT ADJUST-
MENTS THAT ARE CRITICAL FOR SAFE OPERATION ARE
IDENTIFIED IN THIS MANUAL. FOLLOW THESE PROCEDURES
WHENEVER CRITICAL COMPONENTS ARE REPLACED OR IM-
PROPER OPERATION IS SUSPECTED.
¡
21T3 (E)
3
POWER SAVING FUNCTION
If your computer is equipped with power management, the monitor can support this func-
tion fully. Here the monitor does not distinguish between the individual energy-saving modes
of the computer (standby mode, suspend mode and OFF mode), as it is capable of immedi-
ately switching into the mode with the highest energy-saving effect.
Stage
ON
Energy-saving mode
Power indicator
glows green
glows orange
Function
Monitor
Monitor
operating
is dark
normally
Power consumption
normal 135 W
reduced to < 3 W
If your PC detects inactivity (no input) it sends an appropriate signal to the monitor to
reduce the power consumption (energy-saving mode). The power indicator of the monitor
changes colour to indicate the status change.
Once an input is mode at the PC the screen contents are redrawn and full power is restored.
For detailed information on how energy-saving mode operates refer to the Operating Manual
or Technical Manual of your PC.
When the monitor is switched to the energy-saving mode by the power management system
a power consumption of up to 3 W is maintained to feed the circuit for redrawing the screen
contents.
To completely switch off the power consumption, switch off the monitor or the system unit.
21T3 (E)
4
879767318.016.png 879767318.017.png 879767318.018.png
 
DIAGNOSIS
Failure
Power LED
+B failure
Amber
Off
(0.5 sec)
(0.5 sec)
Horizontal / Vertical Deflection
failure, Thermal protector
ABL protector
Amber
Off
(1.5 sec)
(0.5 sec)
Amber
Off
(0.5 sec)
(1.5 sec)
HV failure
Amber
Off
Amber
Off
(0.25 sec)
(0.25 sec)
(0.25 sec)
(1.25 sec)
Aging / Self Test
Amber
Off
Green
Off
(0.5 sec)
(0.5 sec)
(0.5 sec)
(0.5 sec)
Out of scan range
Green (OSD indication)
Aging Mode (Video Aging) : During Power Save, press MENU button for longer than 2 second.
Self Test (OSD Color Bar)
: During Power Save, push button for longer than 2 second.
+
21T3 (E)
5
879767318.019.png 879767318.020.png 879767318.021.png 879767318.022.png 879767318.023.png 879767318.024.png 879767318.025.png
 